To load the program into MZ-800:

Load the program after switching on the MZ-800 into the IPL system (press key "C"). The program
starts automatically.

To load the program into MZ-700:

Load the program into the monitor with LOAD-command (press key "L").

Operating instructions

The program is resident in the storage from $C000 to $CE00.

If the program is loaded the prompt symbol ">" is shown. The program awaits commands.

You'll return to the prompt while executing a command mostly by pressing SHIFT/BREAK
coincidentally. If not, press the RESET key at the reverse side of the MZ. The program can be
reexecuted by "JC400". This is a warm start, all data remain in the storage.

You can pause a complex listing by pressing the space bar and you can restart the listing by
pressing the space bar again or by CR.

Commands

A
ASCII-listing
Type in a 4 digit hexadecimal address after pressing key "A". The storage will be listed from
this address ASCII formatted.

B
Set break point
Type in a 4 digit hexadecimal address after pressing key "B". Use this command to view the
contents of all registers when the breakpoint is reached. Setting further breakpoints will
deactivate a previous breakpoint. This means, you can use one breakpoint only at a time. If you
need more than one breakpoint put $FF at the address where the breakpoint is needed.

C
Binary-listing
Type in a 4 digit hexadecimal address after pressing key "C". The storage will be listed from
this address binary formatted.

D
Disassemble
Type in a 4 digit hexadecimal address after pressing key "D". The disassembly will start from
this address. Now type in a second 4 digits hexadecimal address. The disassembly will stop at 
this point. The disassembler will show Z80 mnemonics, address- and hexvalues, ASCII values.

E
Use this command to see how commands manipulate the accumulator register A. For example, to see
the contents of the accu after two instructions RLCA first type in the operation code of RLCA 
twice: 07 07. Next type in the data to be manipulated within the accu, for example 11. The
response of this submonitor will be 44. The contents of the accumulator is rotated left twice.

F
Find
To find a combination of bytes in the storage you have to type in a 4 digits hex address first
to define the begin of the search area. Next type in a 4 digits hex address for the end of the
area to be searched for. Then you can type in any combination of two digits hex values which
represent the argument of the search.
Example: F FROM 0000 TO 1000
         DATA: CD 12 00 ??
The command awaits 4 hex values. Type in ?? for unneeded values. The submonitor displays the
addresses where the specified combination was found. Press the space bar to pause the listing.

O
Input same as described at the find command, but the search argument is a mnemonic code. Must
be delemited by spaces.

G
Goto $
Type in a 4 digit hexadecimal address after pressing key "G". The program will be executed
starting from the specified address.

I
Displaycode-listing
Type in a 4 digit hexadecimal address after pressing key "I". The storage will be listed from
this address display code formatted.

J
Show flags
The actual contents of the flag register will be displayed.

K
Fill memory area
You can fill a specified memory area by a specified constant. Type in 4 digits hex values for the 
begin and the end of the area, then type in a two digits hex value which represents the character
to be filled into the area. Don't use my area from $C000 to $CE00.. don't kill me ;)

L
Load
Loads a program from the data recorder. The program will not be executed, but the start address,
the end address, and the file name will be displayed.

M
Memory dump
Type in a 4 digit hexadecimal address after pressing key "I". The storage will be listed from
this address hexadecimal formatted. Type in a second hex value that represents the end address of
the area to be dumped. Press the space bar to pause the listing.

N
Type in an 8 digit binary value. This will be translated into its hex value and displayed.

Q
Compare memory areas
Type in 4 digits hex addresses for the begin and the end of the first area, then type in a 4
digits hex address for the begin of the second area to be compared with the first area. If any
difference is found the contents of both areas will be displayed.

Y
Load to
Loads a program from the data recorder to a specified address. To this type in a 4 digits hex 
address where the program is to be loaded.

R
Show contents of all registers.

S
Save
Save a memory area (a program or data) to the data recorder. To this type in S. Then you will be
prompted to type in the filename. Next type in the attribute of the file, for example $01 for a
machinecode program. Now type in 4 digits hex addresses for the begin, the end, and the execution
address (auto load address. Use $00AD if not needed) of the memory area to be saved.

T
Text input
You can type in any text to be stored into the memory at a specified address. To this type in a
4 digits hex address for the target address of the text. Next type in your text. $0D is suffixed
automatically by pressing CR at the end of the text. Use uppercase and lowercase letters only.

U
Gosub
Executes a subroutine that transfers the control back by a RET command ($C9). To this type in a
4 digits hex address for the execution address of the subroutine.

V
Verify
Verifies a program saved by the save command S.

W
Write hex values into memory
To this enter a 4 digits hex address that represents the begin of the memory area where you want to
type in hex values (start address). Then type any combinations of two digits hex values.

X
Transfer memory area (block)
Type in 4 digits hex addresses for the begin and the end of the area to be copied, then type in a
4 digits hex address for the begin of the target area where the area is to be copied to. Take care
in the case of overlapping and the area of the submonitor ($C000 - $CE00).

Z
Type in a 2 digits hex value. This will be translated into its binary value and displayed.

 (pound symbol)
Type in a 2 digits hex value. This will be translated into its decimal value and displayed.

!
Goback to monitor. Restart the submonitor by JC400.

0
Programmable function key. To this type in a 4 digits hex address. Read the following command.

S & 0
Press S and 0 coincidentally. The jump address previously specified by the command 0 will be 
executed.

9
Programmable function key. To this type in a 4 digits hex address. Read the following command.

S & 9
Press S and 9 coincidentally. The subroutine previously specified by the command 9 will be 
executed.

-
Subtract
Type in any two 4 digits hex values. The second value will be subtracted from the first value and 
the result is displayed. The zero flag and/or the overflow flag are displayed too.

+
Add
Type in any two 4 digits hex values. The values will be added and the result is displayed.
The zero flag and/or the overflow flag are displayed too.

/
Repeat last disassembled area.
