BOARD
     ID = "ICU1280"
     NAME = "Sumo SPI 200"
     MFR = "Sumo Systems"
     VERSION = 1,0
     CATEGORY = "MSD"
     SLOT = ISA16
     COMMENTS = "Sumo SPI 200 Formaly the SCSI AT-R1"
                 
JUMPER(1) = 10
     NAME = "JP1"
     JTYPE = PAIRED
     VERTICAL = YES
     LABEL = LOC(1-10)  "1" "2" "3" "4" "5" 
                        "6" "7" "8" "9" "10"
                        
     FACTORY = LOC(1-10) 1011010111

JUMPER(2) = 8
     NAME = "Interrupt"
     JTYPE = PAIRED
     VERTICAL = NO
     LABEL = LOC(1-8) "1" "2" "3" "4" "5" "6" "7" "8"
     INITVAL = LOC(1-8) 00000010
     FACTORY = LOC(1-8) 00000010


FUNCTION = "BIOS Address"
     CHOICE = "D8000"
       FREE
       MEMORY = 16K
       ADDRESS = 0D8000H
       WRITABLE = NO
       MEMTYPE = OTH
       SHARE = NO
       INIT = JUMPER(1) LOC(4-6) 101
     CHOICE = "C8000"
       FREE
       MEMORY = 16K
       ADDRESS = 0C8000H
       WRITABLE = NO
       MEMTYPE = OTH
       SHARE = NO
       INIT = JUMPER(1) LOC(4-6) 111
     CHOICE = "CC000"
       FREE
       MEMORY = 16K
       ADDRESS = 0CC0000H
       WRITABLE = NO
       MEMTYPE = OTH
       SHARE = NO
       INIT = JUMPER(1) LOC(4-6) 011 
     CHOICE = "DC000"
       FREE
       MEMORY = 16K
       ADDRESS = 0DC0000H
       WRITABLE = NO
       MEMTYPE = OTH
       SHARE = NO
       INIT = JUMPER(1) LOC(4-6) 001 

FUNCTION = "I/O Port Address"
     CHOICE = "310H"
       FREE
       PORT = 0310H
       SHARE = NO
       INIT = JUMPER(1) LOC(7-10) 0111
     CHOICE = "300H"
       FREE
       PORT = 0300H
       SHARE = NO
       INIT = JUMPER(1) LOC(7-10) 1111
     CHOICE = "320H-370H"
       LINK
       PORT = 0320H-0380H STEP = 16
       SHARE = NO
       INIT = JUMPER(1) LOC(7-10) 1011 | 0011 | 1101 | 0101 | 1001 | 0001

FUNCTION = "IRQ Request"
   CHOICE = "IRQ14"
      FREE
      IRQ = 14
      INIT = JUMPER(2) LOC(1-8) 00000010
   CHOICE = "IRQ3"
      FREE
      IRQ = 3
      INIT = JUMPER(2) LOC(1-8) 10000000
   CHOICE = "IRQ4"
      FREE
      IRQ = 4
      INIT = JUMPER(2) LOC(1-8) 01000000
   CHOICE = "IRQ5"
      FREE
      IRQ = 5
      INIT = JUMPER(2) LOC(1-8) 00100000
   CHOICE = "IRQ10"
      FREE
      IRQ = 10
      INIT = JUMPER(2) LOC(1-8) 00010000
   CHOICE = "IRQ11"
      FREE
      IRQ = 11
      INIT = JUMPER(2) LOC(1-8) 00001000
   CHOICE = "IRQ12"
      FREE
      IRQ = 12
      INIT = JUMPER(2) LOC(1-8) 00000100
   CHOICE = "IRQ15"
      FREE
      IRQ = 15
      INIT = JUMPER(2) LOC(1-8) 00000001

FUNCTION = "Zero Wait State"
   CHOICE = "Enabled"
      FREE
      INIT = JUMPER(1) LOC(1) 1
   CHOICE = "Disabled"
      DISABLE = YES
      FREE
      INIT = JUMPER(1) LOC(1) 0

FUNCTION = "Floppy Drive"
   CHOICE = "Enabled"
      FREE
      INIT = JUMPER(1) LOC(3) 1
   CHOICE = "Disabled"
      DISABLE = YES
      FREE
      INIT = JUMPER(1) LOC(3) 0
